Test facility includes:
  • turbine casing (used for core components installation),
  • two water brakes (load device),
  • main, extraction and auxiliary condensers,
  • control and stop valves,
  • alive steam pipelines,
  • condensed and cooling water pipelines,
  • pumps,
  • pressure and temperature reduction devices,
  • steam ejection,
  • oil system,
  • safety and control systems.
The special driven turbine (Curtis type) is available.
In order to obtain easy access to core components (fast changing of exhaust details) there are two manholes in outer casing.

Main media and geometry parameters of rig:
#ParameterUnitValue
1Media  
1.1Steam mass flowkg/sup to 15,0
1.2Inlet steam pressureMPaup to 0.55
1.3Inlet steam temperatureKup to 530
1.4BackpressurekPa3-15*
2Geometry  
2.1Number of stages-3-5
2.2Number of shafts-2
2.3Max diameter of LSBmm1400
2.4Rotation speedrpm9500
*Wider backpressure range could be achieved for special tests.

 