| System
| Obtained results
| Description
|
Mass flow measurement |
Values of steam and water mass flows going through different control sections
such as inlet, extraction and outlet
|
Either calibrated nozzles or weighting system
|
Torque measurement |
Values of force on the lever of water brake
|
Force is measured by dynamometers
|
| Thermodynamic parameters |
Static pressures and temperatures along flow path, droplet diameters and
wetness concentration
|
About 200 sensors could be used for static
pressure measurement (the measuring scheme is "one tapping-one line-one sensor"
and about 20 thermocouples are available on test bench. Special optic devices
developed in CKTI could do wetness measurements
|
| Aerodynamic parameters |
Flow velocity components and flow angles
|
The test bench outer casing has special places for aerodynamic probes
installation. Probes are used for flow path traversing
|
Vibration and structure mechanical parameters |
Displacements, clearances, blades and shafts oscillation characteristics
|
The different types of sensors are used (such as inductive,
whirl-current or strain gage)
|
The calibration of instrumentation are performed by Mendeleev Russia National Me
trology Center (Mendeleev Institute).